
Touch-screen paperless recorder
7 in 800×480 touch · up to 24 isolated inputs · 1 s on every channel
0.2 % F.S., 16 alarm relays, 8 retransmission outputs, Modbus RTU and TCP
Ten models across four families, made here rather than traded. The measuring ones sit in a panel, on a duct or on a wall. The recording ones exist because somebody has to prove what the temperature was, months later.
Recorders that keep the record, transmitters that put a measurement on a 4–20 mA loop, displays that put it on a wall, and modules that put twelve channels on RS-485.

7 in 800×480 touch · up to 24 isolated inputs · 1 s on every channel
0.2 % F.S., 16 alarm relays, 8 retransmission outputs, Modbus RTU and TCP

4 in color · 6 isolated inputs · 1 s sampling
0.2 % F.S., 6 alarm relays, 2 retransmission outputs, Modbus RTU

12 channels · thermal print · 120 mm folded chart
0.2 % F.S., 10–450 mm/h chart speed, 24 VDC distribution

Split stainless probe · digital display · 4–20 mA and RS-485
−40 to 80 °C, 0–100 % RH, ±0.3 °C and ±3 % RH, IP65

304 stainless probe · 1 MPa sealed thread · up to 120 °C
−40 to 120 °C, 0–100 % RH, SHT31 sensor, IP65

350×260 mm · 1.8 in digits · sound and light alarm
0–100 % RH, ±3 % RH, alarm at 60 dB, relay output

272×192 mm · 1.5 in digits · 24 VDC
0–100 % RH, ±3 % RH, sound and light alarm, RS-485

DIN rail · through-bore 4, 8 or 15 mm · no polarity
±0.3 % F.S., 4–20 mA into 550 Ω, T90 ≤ 200 ms, 2.5 kV isolation

Ø22 mm bore · 120 % over-input for 24 h · no polarity
±0.3 % F.S., 4–20 mA into 550 Ω, T90 < 400 ms, 2.5 kV isolation

12 channels · current, voltage, RTD or thermocouple · stacks on rail
±0.2 % F.S. on current and voltage, ±0.5 °C on Pt100, Modbus RTU
Specifications above are the published figures for each model. Range, output and supply are fixed per variant, so the exact item you need is a model plus those three choices — send the application and we come back with the code. Drawings and the full parameter sheet for any model are available on request.
The short version, for choosing between them. Everything here is drawn from the current datasheets — if a number is not in this table, we would rather send you the sheet than guess.
| Model | Function | Channels and range | Output and communication | Size |
|---|---|---|---|---|
| PLR3000 | Touch-screen paperless recorder | 24 isolated universal inputs, 32 by expansion, 1 s sampling | Modbus RTU + Modbus TCP, USB 2.0, 64 MB internal | 187×147×145 mm |
| PLR1200 | Color-screen paperless recorder | 6 isolated universal inputs, 1 s sampling | Modbus RTU, USB 2.0, 16 MB internal | 160×80×90.5 mm |
| KRM1300 | Paper chart recorder | 12 channels, 120 mm × 8 m thermal chart | Relay and 4–20 mA outputs, 24 VDC distribution | 144×144×233 mm |
| THK300 | Temperature and humidity transmitter | −40 to 60 / 80 / 120 °C by version, 0–100 % RH | 4–20 mA or 1/5/10 V, RS-485 Modbus RTU | 120×104×41 mm |
| THK210 | Duct temperature and humidity transmitter | −40 to 120 °C / 0–100 % RH, 1 MPa seal | 4–20 mA into 500 Ω, 5/10 V, RS-485 Modbus RTU | 117×85×41 mm |
| THS350 | Temperature and humidity display | −20 to 120 °C by version, 0–100 % RH, 1.8 in digits | RS-485 Modbus RTU, relay, 60 dB alarm | 350×260×50 mm |
| THS270 | Temperature and humidity display | −20 to 120 °C by version, 0–100 % RH, 1.5 in digits | RS-485 Modbus RTU, relay, 60 dB alarm | 272×192×33 mm |
| DLA100 | AC current transmitter | AC current or voltage, 40–60 Hz, bore 4/8/15 mm | 4–20 mA into 550 Ω, 24 VDC supply | DIN 35 rail |
| DLA200 | AC current transmitter, Ø22 mm bore | AC current, 40–60 Hz, 120 % over-input | 4–20 mA into 550 Ω, 24 VDC supply | DIN 35 rail |
| MLK1000 | Analogue to RS-485 module | 12 channels: 4–20 mA, 0–10 V, RTD, thermocouple | RS-485 Modbus RTU, 8–30 VDC | 71.5×102.5×44 mm |
An instrument is a model plus the choices below, not a catalog number to look up. These are the axes we set per order; anything not on the list is a conversation, not a refusal.
| Parameter | What you choose |
|---|---|
| Range | Follows the version you pick — integrated or remote probe, standard, extended or high-temperature |
| Output | 4–20 mA, 1/5/10 V, relay or none; where a model offers a choice, it is set per order |
| Communication | RS-485 Modbus RTU on every instrument; Modbus TCP and USB on the recorders |
| Probe and form | Integrated or remote probe, duct probe, through-bore size, panel or wall mount |
| Supply | 12 VDC, 24 VDC or 100–240 VAC, depending on the family |
| Identity | Your logo, model number, label, manual and packaging |
Every instrument on this page is assembled on our own SMT lines and calibrated against a reference before it leaves. That is the reason the range exists: it is the kind of product our equipment was bought for.
Full private label terms, including minimum order, are on the finished goods page.
Tell us what you are measuring, where it is installed and which output your system expects. You get the model code, the datasheet and a price — and a straight answer on lead time.